SEL, SELECT


NAME
SEL, SELECT - select specified atoms. Overwrite the previous selection.

SYNOPSIS
SEL chain_identifiers/residue_serials/residue_names/atom_names
SEL residue_ranges
SEL residue_names
SEL ATO atomic_ranges
SEL keyword
SEL ELE chemical_symbol
SELECT chain_identifiers/residue_serials/residue_names/atom_names
SELECT residue_ranges
SELECT residue_names
SELECT ATOMS atomic_ranges
SELECT keyword
SELECT ELEMENT chemical_symbol

DESCRIPTION
Select specified atoms. Atoms are selected according to the specified cryteria. Six types of selection are available:

(1) detailed selection;
(2) selection by residue serial numbers;
(3) selection by residue names;
(4) special selection (by keyword);
(5) selection by chemical symbol;
(6) selection by atom serial number.

DETAILED SELECTION
In this case four data types are specified simultaneously: chain identifiers, residue serial numbers, residue names and atom names. It is not possible to specify atomic serial numbers. The selection string should contain exactly three slashes, separating different data types:

chain_identifiers/residue_serials/residue_names/atom_names.

Both uppercase and lowercase characters are accepted. Space ( ), comma (,) and semicolon (;) may be used as separators.

Chain identifiers are single alphabetic characters. Asterisk (*) may be used to select all chains. The keyword EXC (EXCEPT) may be used to exclude one or more chains from selection.

Residue serial numbers consist of digits. Minus may be used to specify a range of residue serial numbers. For example, 1-100 specifyes residues from 1 to 100, including these two. Asterisk (*) may be used to specify all residue serials. The keyword EXC (EXCEPT) may be used to exclude serial numbers or ranges from selection.

Residue names are expected in three letters code. Asterisk (*) may be used to specify all residue names. The keyword EXC (EXCEPT) may be used to exclude one or more names from selection. Non-standard names are accepted.

The names of atoms are expected as used in the input file; do not replace them with pure chemical symbols. C alpha, for example, should be specified as CA or ca (case is not important), if coordinates are read from PDB file. Asterisk (*) may be used to select all atoms, while EXC may be used to exclude some atoms from selection. Examples:

sel a/*/*/* Select all atoms from chain A.
sel * exc m/*/*/ca Select CA atoms from all chains except chain M.
sel */*/*/* exc ca,c,n,o Select all atoms except CA, C, N and O.
sel a/* exc 72-112/*/ca Select CA atoms from chain A, but exclude residues from 72 to 112.

SELECTION BY RESIDUE SERIAL NUMBERS
To select all atoms in a single residue, a residue range or in a number of residues and residue ranges, a simple syntax may be used. The selection string should contain no slashes. Keyword EXC (EXCEPT) is accepted, but asterisk (*) will be missintepreted. Minus may be used to specify residue ranges. Comma (,), semicolon (;) and space ( ) may be used as separators. Examples:

sel 1-100 Select residues from 1 to 100.
sel 1-100 exc 20-40 Select residues 1-100 but exclude 20-40.
sel 1, 4, 8, 11-48 exc 20-32 Select residues 1, 4, 8 and 11-48 but exclude 20-32.

SELECTION BY ATOMIC SERIAL NUMBERS
To select a single atom by the atomic serial number, combine the command SEL (SELECT) and the keyword ATO (ATOMS). For example, to select the atom number 102 type:

sel ato 102

The same keyword may be used to select a range of atoms or two or more ranges. Examples:

sel ato 1-100 Select atoms which have serial numbers in the range between 1 and 100.
sel 1-20 40-50 Select atoms which have serial numbers between 1 and 20 and between 40 and 50.

Do not combine the keywords EXC (EXCLUDE) and ATO (ATOMS).

SELECTION BY RESIDUE NAMES
Three letters code should be used. Asterisk (*) and keyword EXC (EXCEPT) are not accepted. Example:

sel phe,tyr,trp Select PHE, TYR and TRP.

SPECIAL SELECTION KEYWORDS
Some special keywords may be combined with SEL (SELECT) to select residues or atoms according to some properties. It is also possible to select the complement, i.e. all atoms which were not selected previously. A single keyword should be used; asterisk (*) and keyword EXC (EXCEPT) are not accepted.

sel *
sel all
Select all atoms (select all).
sel abo
sel above
Select atoms above the plane.
sel aci
sel acidic
Select acidic amino acids (GLU and ASP).
sel ali
sel aliphatic
Select aliphatic amino acids (ILE, LEU and VAL).
sel alt Select atoms at alternate positions.
sel bad Select bad residues. A residue is treated as bad if the
peptide bond assigned to this residue is non-planar.
The peptide bond is non-planar if the omega angle is
different for 20 or more degrees from 0 or 180 degrees.
sel bas
sel basic
Select basic amino acids (ARG, LYS and HIS).
sel bel
sel below
Select atoms below the plane.
sel cha
sel charged
Select charged amino acids (ARG, LYS, HIS, GLU and ASP).
sel cis Select cis residues.
sel com
sel complement
Select atoms which were not selected previously.
sel het
sel hetero
Select hetero atoms (heme groups, water etc.).
sel pho
sel hydrophobic
Select hydrophobic amino acids
(ALA, ILE, LEU, MET, PHE, TRP, VAL, TYR, CYS, GLY and HIS).
sel mai
sel main_chain
Select main chain atoms (CA, C, N and O).
sel mod serial_number
sel model serial_number
Select model specified by serial_number.
NMR structure is a set of models. Example: sel mod 1
sel neg
sel negative
Select negatively charged amino acids (GLU and ASP).
sel pol
sel polar
Select polar amino acids
(ARG, LYS, HIS, ASP, GLU, ASN, GLN, SER, THR, TRP and TYR).
sel pos
sel positive
Select positively charged amino acids (ARG, LYS and HIS).
sel seq
sel sequence
Select sequence fragments which match the sequence stored
to the sequence buffer. The sequence buffer should be
initialized before executing this command.
sel sid
sel side_chains
Select atoms which belong to side chains (all except CA, C, N and O).
sel sma
sel small
Select small amino acids
(GLY, ALA, SER, THR, CYS, VAL, PRO, ASP and ASN).
sel sph
sel sphere
Select atoms inside the sphere. Use the command
RAD (RADIUS) to set the sphere radius.
sel tm Select the transmembrane part
(useful for membrane proteins).
sel abo
sel above
Select atoms above the plane.
sel tra
sel trans
Select trans residues.
sel tri
sel triplet
If there are three (or more) positively charged residues in a fragment
of up to five protein residues, select them. Detailed explanation may
found in the article:
D. Juretic, L. Zoranic and D. Zucic,
Basic charge clusters and predictions of membrane protein topology,
Journal of Chemical Information and Computer Sciences 42, No. 3,
620-632 (2002).

SELECTING CHEMICAL ELEMENTS
To select certain chemical element, use the keyword ELEMENT (short form: ELE) and the standard chemical symbol. To select iron, for example, you should type the following command:

sel ele fe

In addition to real chemical elements, garlic accepts two imaginary elements: "jellium" (J) and "quarkonium" (Q). Jellium is inert and it never binds to neighboring atoms, no matter how close they are. Quarkonium binds to other quarkonium atoms which have adjacent atomic serial numbers. For example, if some quarkonium atom has serial number i, it may form bonds with quarkonium atoms i-1 and i+1. The interatomic distance is not important! Both elements were introduced to enable drawing of special objects. Quarkonium may be used to draw polygonal lines in three dimensions. The original idea was to adapt garlic for visualization of some medical data. For example, quarkonium may be used to represent blood vessels and jellium to represent retraction balls characteristic for broken axons in human brain. By the way, quarkonium is a serious thing in high energy physics, but there it looks quite different. Note that symbols J and Q are not used in the periodic table of elements.

NOTES
(1) The command SELECT resets the editing mode to default (no editing).

(2) The keyword TM may be used to select the transmembrane part of the protein. In addition to the atoms which lay between two planes which define the membrane, some outside atoms will be taken into account, if they don't lay more than two anstroms from the nearest plane. This should ensure that some hydrophobic residues close to the edge will not be excluded from the selection. RELATED COMMANDS
ADD expands the previous selection. RESTRICT restrics the previous selection.